Documentation › Buckling and natural frequencies
Buckling and natural frequencies
Two more answers from the same study: the load at which a slender structure buckles, and the frequencies it vibrates at.
Linear buckling
A slender column or frame can fail by buckling sideways at a stress far below yield. The stress plot does not show this. Buckling does.
- Open Settings on the Study tab and tick Linear buckling. Modes is how many buckling shapes to find; the first is the one that matters most.
- Solve.
- On the Results tab, open the arrow beside Modes and choose a buckling mode.
Each mode has a load factor and a shape. The factor multiplies all the applied loads, gravity included: a factor of 3.2 means the structure buckles in that shape at 3.2 times the loads you applied. A factor below 1 means it buckles before it reaches them.
The shape shows how it buckles, not how far: its size on screen means nothing. Animate it to see which members go.
Linear buckling assumes a perfectly straight, perfectly made structure. Real ones buckle earlier, so keep a margin. Factors of 3 or more are common practice.
Natural frequencies
Every structure has frequencies at which it rings. A motor, a pump or footfall near one of them shakes it far more than the size of the force suggests. Find them to keep a frame clear of the machine that sits on it.
- Open Settings and tick Natural frequencies. Frequencies is how many to find, from the lowest.
- Hold and load the model as for a static study, and solve.
- Open the arrow beside Modes and choose a vibration mode, such as “Vibration mode 1 (217 Hz)”. Animate it to see the shape swing either side of rest.
The report has a table of the frequencies and pictures of the first three shapes. The results also say how far the last pass moved each frequency. A coarse model reads high, so if they are still moving, solve a pass more.
What it does not do
- The frequencies are those of the model as it is held. Change a fixture and they change.
- The loads play no part. A member in tension is not stiffened by it.
- Remote masses are not counted. For a motor on a frame, model the motor as a block of the right mass, or expect the real frequency to be lower than the one reported.
- There is no damping, and no response to a force that varies in time: you get the frequencies and shapes, not how far the structure moves when shaken.
- Single parts are checked against published benchmarks, on the accuracy page. An assembly of several parts has not been compared with a reference of its own.
Something wrong or missing on this page? Tell us.